👍 What we like
- Local real-time reading, no subscription or cloud
- Peak/off-peak registers, Tempo and next-day color available
- kWh registers work directly in the Energy dashboard
- The customer terminal block is designed for this, no Enedis visit needed
👎 What to watch
- Power is reported in VA, not watts
- Only 130 mW on terminal A: not enough for an ESP on Wi-Fi
- USB-port Linky meters without terminal A are incompatible with the ZLinky
- The Enedis cloud only provides the previous day's data
📑 Contents ▾
- 01 The Linky TIC port: three terminals, two modes
- 02 Switching the TIC to standard mode
- 03 The ZLinky_TIC Zigbee module: the easiest to install
- 04 ESP32 and ESPHome, Raspberry Pi shield: the Wi-Fi or wired route
- 05 The Enedis cloud integration: no hardware, but one day behind
- 06 What each option gives you
- 07 When the TIC isn’t an option: the current clamp
- 08 Wiring it safely: what’s allowed and what isn’t
- Our picks
The simplest way to track your Linky consumption live in Home Assistant is still a module that plugs into the meter’s customer tele-information (TIC) port. If you already run a Zigbee network, or plan to build one, get a Zigbee module powered by the meter: it needs no battery and no cable. If you’re comfortable with electronics and there’s an outlet near the meter, an ESP32 running ESPHome with an optocoupler does the same job over Wi-Fi. If your meter is out of reach, for example in a box at the edge of your property, you can still use the Enedis cloud integration: it only delivers the previous day’s data, but that’s enough for the Energy dashboard. The information on this page comes from documentation by Enedis, LiXee, Zigbee2MQTT, ESPHome and the ha-linky project, checked in November 2026. Selfhostr has not tested these products.
The Linky TIC port: three terminals, two modes
The Linky’s customer terminal block sits under the small green cover on the front of the meter. It has three terminals used for tele-information:
- I1 and I2 carry the data: an amplitude-modulated signal on a 50 kHz carrier, with no polarity to respect on the reader side;
- A, together with I1, supplies a small amount of power. According to the Enedis specification, the meter guarantees about 130 mW to the receiver. That’s enough for a low-power Zigbee module designed for it, but not for an ESP32 transmitting over Wi-Fi.
The same terminal block also carries the C1/C2 dry contact, which often drives the off-peak contactor for the water heater. That contact can be on a 230 V circuit: don’t touch it, and don’t confuse those terminals with the TIC ones.
The TIC runs in two modes:
| Historique mode | Standard mode | |
|---|---|---|
| Baud rate | 1200 baud | 9600 baud |
| Factory default | yes | on request |
| Typical labels | BASE, HCHC/HCHP, BBRH… (Tempo), PTEC, IINST, PAPP | EAST, EASF01 to EASF10, NTARF, SINSTS, URMS1, IRMS1, EAIT |
| Voltage, export | no | yes (URMS1, EAIT) |
Historique mode reuses the format of the older electronic meters so that existing equipment keeps working. Standard mode adds voltage, exported energy (useful if you have solar panels), up to ten supplier registers and messages from the meter.
One thing often catches people out: in both modes, the instantaneous power sent is apparent power in VA (PAPP or SINSTS), not active power in watts. In a home without large motors the gap is modest. Even so, don’t compare it watt for watt with a smart plug that measures watts.
Switching the TIC to standard mode
First check the current mode: scroll through the meter’s display with the + and − buttons, and it shows the TIC mode. To change modes, you ask your electricity supplier, not Enedis. The supplier passes the request to the grid operator, which switches the meter remotely, with no technician visit. On a Linky, this service is free of charge.
Before asking for the change, list everything that already reads the TIC in your home: an energy manager, a solar diverter or an old display may only understand historique mode and stop working. Conversely, switching to standard is pointless if all you want is the peak/off-peak registers and power: historique mode already provides them. It becomes useful for voltage, exported production, plans with more than two rate periods, and detailed three-phase data.
Once the switch is done, set the reader to the new mode as well: 9600 baud in ESPHome, linky_mode set to auto or standard in Zigbee2MQTT, then restart the module.
The ZLinky_TIC Zigbee module: the easiest to install
LiXee’s ZLinky_TIC v2 plugs straight into the TIC terminal block under the green cover and draws its power from the meter. LiXee states that this hardware version, with firmware v14, is certified “Linky Ready” by the Enedis lab. It works with ZHA, Zigbee2MQTT and deCONZ in Home Assistant, as well as with Jeedom, Domoticz and Homey. It has an extension port that passes I1/I2 through to another tele-information reader.
What to know before buying:
- Incompatible meters: LiXee notes that Iskra, Itron or Landis+Gyr Linky meters with a USB port have only two tele-information pins. The ZLinky can’t draw power on those models. Look at your terminal block before ordering.
- You need a Zigbee coordinator on the Home Assistant side, meaning a USB dongle. The ZLinky doesn’t connect to your Internet router by itself.
- Range: the meter is often in a utility shaft, a metal cabinet or a garage. A mains-powered Zigbee router placed between the meter and the coordinator, such as a smart plug, fixes most link problems. LiXee also offers an external antenna option, but its page states that it requires drilling the meter cover.
- Router role: with only 130 mW available, several users have seen instability when battery devices pair through the ZLinky. The community uses a “Limited” firmware that refuses those battery devices, and switching firmware type over OTA has its own constraints. The safest approach is not to count on the ZLinky to extend your mesh.
- Solar production: the export register (
EAIT) only exists in standard mode. According to LiXee, it isn’t sent on self-consumption contracts with no sale of surplus (CACSI).
In Zigbee2MQTT, the linky_mode, energy_phase (single- or three-phase) and tarif options keep dozens of empty attributes from showing up. The ZLinky page on Zigbee2MQTT lists everything that’s exposed, including the next day’s Tempo color. If you’re starting from scratch, our Zigbee2MQTT with Home Assistant guide and our Zigbee dongle comparison cover setting up the coordinator.
ESP32 and ESPHome, Raspberry Pi shield: the Wi-Fi or wired route
ESPHome includes a teleinfo component that decodes both modes. According to the ESPHome documentation, you only need to connect the output of an optocoupler (with its resistor) to a UART RX pin, then declare the labels you want:
uart:
rx_pin: GPIO16
baud_rate: 9600 # 1200 en mode historique
parity: EVEN
data_bits: 7
teleinfo:
id: linky
historical_mode: false # true en mode historique
sensor:
- platform: teleinfo
tag_name: "EAST"
name: "Linky index total"
- platform: teleinfo
tag_name: "SINSTS"
name: "Linky puissance apparente"
What most often goes wrong in a DIY build:
- Power: terminal A isn’t enough for an ESP on Wi-Fi. Plan a separate USB power supply, which means an outlet near the meter or a cable running to the panel. A module that “drops off” for no reason is almost always short on power.
- The right baud rate: an ESP set to 1200 baud on a meter in standard mode receives nothing usable, and vice versa. The serial format is 7 data bits with even parity.
- UART on the ESP32: if you use the serial port for logging or Improv, wire the TIC to a second UART to avoid conflicts.
- Isolation: the optocoupler separates the meter line from your electronics. Never wire I1/I2 directly to an ESP pin.
Ready-made ESP-based Wi-Fi modules are also sold by small French makers. Before buying one, check three things: standard mode support, how it’s powered (external or from the TIC), and whether you can flash it with ESPHome. If your Home Assistant runs on a Raspberry Pi installed near the panel, a tele-information shield on the Pi’s serial port, or a TIC-to-USB adapter, avoids wireless altogether. These boards also read both modes, as long as you set the baud rate.
The Enedis cloud integration: no hardware, but one day behind
If the meter is out of reach, the community add-on ha-linky pulls your data from Enedis through the Conso API service and feeds it into the Energy dashboard. You need:
- an Enedis customer account, with hourly load-curve collection enabled;
- a Conso API token.
On first launch, the add-on imports up to one year of daily history. The last seven days come in at 30-minute resolution. A day’s data is only available the next day, and syncing happens in the morning. So you get no instantaneous power, and no automations like “turn off the water heater if power goes above a threshold.” The add-on installs as a Home Assistant app (Home Assistant OS). Its author describes the Docker install as unsupported. It also depends on a third-party service with rate limits: a configuration stuck in a loop can get your token blocked.
What each option gives you
| Zigbee TIC module | ESP32 / ESPHome | Enedis cloud (ha-linky) | |
|---|---|---|---|
| Instantaneous power | yes (VA) | yes (VA) | no |
| Peak/off-peak registers, Tempo | yes | yes | consumption imported, rate split must be configured |
| Next-day Tempo color | yes (exposed by Zigbee2MQTT) | depends on declared labels | no |
| Voltage, export | in standard mode | in standard mode | production if a production meter is configured |
| Power supply | from the meter | external | none |
| Delay | a few seconds | a few seconds | next day |
For the Energy dashboard, don’t use power: set the kWh registers as the consumption source (EAST, or HCHC and HCHP separately to get cost per rate). With a local reading it fills in continuously. With the cloud, it fills in the next day.
When the TIC isn’t an option: the current clamp
With an outdoor meter box or a meter in a building’s shared areas, you can still get real-time power from a metering module installed in your panel, such as the Shelly EM Gen3 with its current clamp, which integrates locally with Home Assistant. It measures what flows through your cable, not what the meter bills. It also knows nothing about the registers or the Tempo color: pair it with the cloud add-on if you want both. Installing it in an electrical panel means switching off the main breaker. If you aren’t qualified, hire an electrician. To measure device by device, see also measuring your homelab’s power consumption.
Wiring it safely: what’s allowed and what isn’t
- Allowed: opening the green cover of the customer terminal block and plugging in a module, or two wires, on I1/I2 (and A if the module uses it). That terminal block exists for exactly this.
- Forbidden: opening the meter itself, breaking a seal or removing the sealed housing. The meter belongs to the public grid. If the terminal block cover is sealed at your place, contact Enedis rather than forcing it.
- Avoid: touching the C1/C2 contact, running long untwisted wires through a shaft that holds power cables, or powering an ESP from terminal A.
- Inside the electrical panel (DIN-rail adapter, USB power supply, clamp): switch off the power before working.
Key facts
Our picks
Affiliate links · same price for youSonoff Zigbee 3.0 USB Dongle Plus-E (ZBDongle-E)
Amazon Black Friday Week runs through November 30
Amazon · price and availability on the listing
Shelly EM Gen3
Amazon Black Friday Week runs through November 30
Amazon · price and availability on the listing
LiXee ZLinkyTIC v2
Amazon Black Friday Week runs through November 30
Amazon · price and availability on the listing
See all our recommended gear in the shop.