👍 What we like
- DSM settings and placement reduce noise without opening the NAS.
- Measured temperature checks before and after each change.
- Reversible replacement procedure if you keep the original fans.
👎 What to watch
- DSM only offers preset modes, no custom fan curve.
- Opening the NAS and fitting third-party parts may void the warranty.
- A fan that spins too slowly can trigger a failure alert in DSM.
📑 Contents ▾
A NAS is audible for three reasons: its fans, its hard drives (spinning platters and head movement) and the vibrations it passes on to the furniture. The most effective approach, without opening the enclosure, is to switch DSM to Quiet mode, enable HDD hibernation and put the NAS on a heavy surface with pads. Replacing the fans comes last, with a risk to the warranty. If you have not bought your NAS yet, the last part of this guide explains what to look for in a model meant for a living room or a bedroom.
This guide uses the Synology DS923+ as its example. First, a common mistake to correct: according to Synology’s datasheet, the DS923+ uses two 92 × 92 × 25 mm system fans. A Noctua NF-A14 PWM, often suggested to make a NAS quieter, is a 140 mm fan. It does not fit in the DS923+. It suits an enclosure with a 140 mm mounting position, such as a self-built NAS in a PC case: our comparison of quiet NAS fans covers that case. For a DS923+, you need a 92 mm fan with the same thickness as the original.
Another important point: opening the enclosure to fit non-Synology parts is not something Synology approves. It may void your warranty. If your NAS is still under warranty, stick to the software and environmental changes (steps 1 to 3) or contact Synology support.
Prerequisites
- A Synology DS923+ (or another model: adapt the dimensions and check its documentation) running DSM 7.x.
- A DSM administrator account and a computer on the same local network as the NAS.
- For the replacement (optional): two 92 mm fans whose thickness and connector match the originals, a Phillips screwdriver, an anti-static wrist strap, something to label the drives with and a phone to take photos.
- A recent backup of your data, for example by following our guide to backing up a NAS to an external drive. Hardware work always carries some risk.
Six steps, from DSM settings to replacing the fans
Step 1: Measure the starting point
Before changing anything, write down the current temperatures so you can compare later. In DSM, the system temperature is shown in Info Center > General. Each drive’s temperature is in Storage Manager > HDD/SSD.
If you prefer the command line, enable SSH temporarily (Control Panel > Terminal & SNMP > Enable SSH service). Connect from your local network only, then list the drives:
ssh your_admin@192.168.1.50
ls /dev/sata* /dev/sd? 2>/dev/null
Then read each drive’s temperature. On DSM 7, internal drives usually show up as /dev/sata1, /dev/sata2… Use the names returned by the previous command.
for d in /dev/sata1 /dev/sata2 /dev/sata3 /dev/sata4; do
echo "== $d"; sudo smartctl -A "$d" | grep -i temperature
done
Check: each drive returns a Temperature_Celsius line (or equivalent) with a value. Note these values along with the time and what the NAS was doing (idle, or running a backup).
If you enabled SSH, disable it once the step 6 checks are done (Control Panel > Terminal & SNMP). Never expose SSH or the DSM interface (ports 5000/5001) to the Internet through port forwarding: for remote access, use a VPN, as in our guide to accessing your NAS remotely with Tailscale.
Step 2: Choose the fan mode in DSM
DSM does not offer a custom fan curve. It offers preset modes, under Control Panel > Hardware & Power > General > Fan Speed Mode. According to Synology’s documentation, the available modes depend on the model and its configuration: Full-Speed, Cool, Quiet and, on some models, Low-Power. Adding a network card may disable some modes to ensure proper cooling.
- Select Quiet Mode (or Low-Power if it is offered).
- Click Apply.
# Check after 24 h of normal use (on the NAS, over SSH)
for d in /dev/sata1 /dev/sata2 /dev/sata3 /dev/sata4; do
echo "== $d"; sudo smartctl -A "$d" | grep -i temperature
done
Check: compare with the step 1 readings, under the same activity conditions. If drive temperatures rise noticeably, switch back to Cool mode. The temperature limits to respect are in your drives’ datasheet.
Step 3: Reduce drive noise and vibration
On a NAS, the hard drives are often louder than the fans.
- HDD hibernation: Control Panel > Hardware & Power > HDD Hibernation. Choose an idle delay. Services that access the volumes constantly (indexing, containers, logs) can keep the drives from spinning down.
- Placement: put the NAS on a heavy, stable surface, not on hollow furniture that acts as a sound box. Leave space behind it for the exhaust air.
- Isolation: rubber or foam pads under the NAS reduce vibration transfer. Never block the air intakes.
# Spot frequent disk access that prevents hibernation (DSM, SSH)
sudo tail -n 50 /var/log/messages
Check: once the chosen idle period has passed, the drives stop making spinning noise. The NAS status LED shows hibernation, as described in your model’s hardware guide.
Step 4: (Optional, out of warranty) Choose replacement fans
Only go ahead with this step if steps 1 to 3 are not enough and you accept the risk of losing the warranty. Synology also sells original fans as spare parts for some models (the Spare Parts section of the Synology website). That is the safest option if a fan has become noisy because it is worn out.
What to check before buying a third-party fan:
- Size: 92 × 92 × 25 mm for the DS923+ according to Synology’s datasheet. Still measure the thickness of the original fan: a thicker model will not fit.
- Connector: photograph the original fan’s connector and the board header. Count the pins and look at the keying. Don’t buy anything until you have confirmed compatibility.
- Minimum speed: DSM monitors fan rotation. A fan whose minimum speed is too low can trigger a “fan failure” alert (beep and notification) even though it works. This is the main trap with “ultra-quiet” models.
# Before buying: check for existing fan alerts
sudo grep -i fan /var/log/messages | tail -n 20
Check: the command should return no recent fan errors. If it does, fix that problem first: a faulty original fan is covered by the warranty.
Step 5: (Optional) Disassemble and replace the fans
- Shut down the NAS from DSM (user menu at the top right > Shut down), unplug the power and network cables, then put on your anti-static wrist strap.
- Label each drive with its bay number, then remove the trays. You will need to put them back in exactly the same place.
- Remove the Phillips screws holding the shell (at the back or on the side, depending on the model; see the hardware installation guide) and slide the shell off carefully.
- Photograph the fan layout, the cable routing and the airflow direction. An arrow is moulded on the frame. On the DS923+, the rear fans push hot air out of the enclosure, and air comes in at the front through the drive bays.
- Unplug one fan, remove it, then fit the new one facing the same way (airflow arrow pointing outwards, like the original). Plug it into the same connector. Repeat for the second fan.
- Keep the cables clear of the blades, put the shell back, screw it in, then return each drive to its own bay.
# After reboot: does DSM respond? (from a PC on the local network)
curl -kI https://192.168.1.50:5001
Check: the command returns an HTTP header (for example HTTP/1.1 200), which shows that DSM is answering on its default HTTPS port (5001; 5000 for HTTP). In Storage Manager, all drives are present and the pool is Healthy.
Step 6: Validate cooling after the replacement
# Fan alerts since reboot
sudo grep -i fan /var/log/messages | tail -n 20
# Drive temperatures
for d in /dev/sata1 /dev/sata2 /dev/sata3 /dev/sata4; do
echo "== $d"; sudo smartctl -A "$d" | grep -i temperature
done
Check: no new fan alerts in the logs or in Log Center, and temperatures close to the step 1 readings under the same conditions. Repeat the check during a heavy task (backup, data scrubbing). If you get a “fan failure” alert, see the next section.
If the fan alert or the noise persists
“Fan failure” alert after the replacement
Cause: the new fan’s speed is too low for DSM, or the connector is not seated properly. Fix: check the connection, then switch to Cool mode: a faster rotation often clears the alert. If it continues, put the original fans back.
A drive or the pool is “degraded” after reassembly
Cause: a drive is not pushed in fully or is in the wrong bay. Fix: shut down the NAS, return each drive to its original bay according to your labels, then check Storage Manager.
The noise is still high
Cause: the noise comes from the drives or vibrations, not the fans. Fix: apply step 3 (hibernation, stable surface, pads).
The “Quiet Mode” option is missing
Cause: the model or an expansion card limits the available modes. Fix: check your model’s specifications in the Synology Download Center.
Choosing a quiet NAS for a living room or bedroom
If you have not bought your NAS yet, noise is decided on the spec sheet. Selfhostr has not measured these models: the values below come from manufacturer spec sheets. Look first at:
- The rated noise level in dB(A), when the manufacturer publishes it. Each brand measures it under its own conditions: compare it with caution from one brand to another.
- The number and size of the fans. On paper, a large fan can spin more slowly than a small one to move the same volume of air.
- The type of storage. Hard drives remain the main source of noise; an all-SSD NAS has nothing spinning apart from its fans. Our HDD vs SSD comparison for a NAS compares their cost per TB, their uses and their noise.
Four models and what their spec sheets say:
- Synology DS920+: according to Synology’s datasheet, a quad-core Intel Celeron J4125 (2.0 GHz, 2.7 GHz burst), 4 GB of DDR4 expandable to 8 GB, four 3.5”/2.5” bays, two M.2 NVMe slots, two 1GbE ports, two USB 3.0 ports and one eSATA port, expandable to nine drives with an expansion unit. It is not fanless: its datasheet lists two 92 mm fans. It also runs DSM: check its documentation for the fan modes it offers.
- Synology DS923+, the model in this guide: dual-core AMD Ryzen R1600, 4 GB of DDR4 ECC expandable to 32 GB, four bays (nine with a DX517 unit), two M.2 NVMe slots, two 1GbE ports and an optional 10GbE module, according to Synology’s datasheet.
- QNAP TS-453D: according to the manufacturer page (QNAPworks), a quad-core Celeron J4125, two 2.5GbE ports, a single 120 mm fan and a rated noise level of 21.1 dB(A). Rated power draw: 11.3 W with drives in standby and 25.98 W in typical operation (TS-453D-4G). No “Urban” variant appears at QNAP, which only lists the TS-453D-4G and TS-453D-8G: check the exact model number on the listing.
- Asustor: the model number “Asustor ADM-A1010-G” does not appear in Asustor’s catalogue: do not buy it under that name without checking the spec sheet. For a truly quiet Asustor, look at an all-SSD model such as the Flashstor 6 FS6706T: six M.2 NVMe slots, Celeron N5105, two 2.5 GbE ports and 18.7 dB at idle according to Asustor’s spec sheet (see the Flashstor 6 FS6706T on Amazon).
In a bedroom, even a discreet NAS can be heard at night when its drives are working. Schedule backups and data scrubbing during the day, and let hibernation do the rest. A closed cabinet muffles the noise but traps heat: leave air behind the unit and check temperatures as in step 1.
Key facts
Our picks
Affiliate links · same price for youSynology DS923+
Amazon · price and availability on the listing
Noctua NF-A14 PWM
Amazon · price and availability on the listing
Synology DiskStation DS920+
Amazon · price and availability on the listing
QNAP TS-453D
Amazon · price and availability on the listing